Late-breaking presentation at Heart Rhythm 2018 shows potential for more patients to benefit from world’s smallest pacemaker

5448
World’s smallest catheter: Micra Transcatheter Pacing System (Medtronic)

An investigational algorithm, utilising the accelerometer signal in the Micra Transcatheter Pacing System (TPS) (Medtronic) may restore AV synchrony, improving cardiac function in patients with sinus rhythm and atrioventricular (AV) block, the results of a new clinical study show.

The results from the MARVEL (Micra atrial tracking using a ventricular accelerometer) feasibility study were presented during a late-breaking session at Heart Rhythm 2018, the Heart Rhythm Society’s 39th Annual Scientific Sessions (9 May–12 May, Boston, USA), and simultaneously published in Heart Rhythm.

“The results of MARVEL indicate that this novel mechanical sensor may allow more patients to benefit from a miniaturised leadless pacemaker,” says Larry Chinitz (NYU Langone’s Heart Rhythm Center, New York City, USA), MARVEL study principal investigator. “Although single-chamber pacing in the ventricle is quite safe for these patients, the preferred option is to treat them with a wired pacemaker in two chambers to maintain synchrony and cardiac function. However, patients with these traditional pacemakers are at risk of experiencing complications related to the pocket and the leads, and leadless pacemakers remove these risks.”

The MARVEL study evaluated 64 patients who already had a Micra TPS at 12 centres in nine countries. Investigators evaluated the ability for the Micra’s accelerometer to monitor and detect contractions in the atrium, even though the device is implanted in the ventricle. Investigators also evaluated Micra’s ability to pace the ventricle to contract in sequence with the atrium, creating AV synchrony. AV synchrony was measured using continuous device telemetry and an electrocardiogram via a Holter monitor.

The study showed the percentage of AV beats in synchrony during pacing with the AV algorithm was 87% among all study patients (while they were at rest for 30 minutes), 80% in high-degree AV block patients, and 94.5% in patients with predominantly intact AV conduction during the study. In patients with high-degree AV block who would benefit the most from AV synchrony, the algorithm yielded significantly greater AV synchrony (P<0.001) compared to VVI pacing without the algorithm. In addition, AV block patients had a statistically significant improvement (P=0.004) in stroke volume (blood flow out of the left ventricle) during AV algorithm pacing (23.9cm LVOT VTI) compared to VVI pacing (21.8cm).

“We are encouraged by the results of MARVEL, which support our commitment to extending the benefits of Micra TPS to broader patient groups,” says Rob Kowal, (Cardiac Rhythm and Heart Failure division, Cardiac and Vascular Group, Medtronic). “We are investing in additional clinical studies to confirm this accelerometer-based leadless pacing approach will benefit patients with AV block who make up approximately 40% of the pacemaker population worldwide.”

The Medtronic Micra TPS was first introduced commercially in Europe in 2015 and in the USA in 2016 for patients who need a single-chamber pacemaker. Comparable in size to a large vitamin, the Micra TPS is less than one-tenth the size of traditional pacemakers, yet it delivers the most advanced pacing technology to patients via a minimally invasive approach. During the implant procedure, it is attached to the heart with small tines, and delivers electrical impulses that pace the heart through an electrode at the end of the device.

Unlike traditional pacemakers, the Micra TPS does not require leads or a surgical “pocket” under the skin, so potential sources of complications related to such leads and pocket are eliminated—as are any visible signs of the device. Micra TPS utilises a miniaturised sensor inside the device to measure patient movement (also known as an accelerometer) and determines appropriate pacing rates based on patient activity levels.

Earlier results presented at the Heart Rhythm Society’s 2018 meeting from the Micra Post-Approval Registry demonstrated major complications with Micra TPS were infrequent with a 63% lower risk for major complication (P<0.001) compared to traditional pacing systems.